Applications
These three – phase dc power supplies of the DNT series supply an unregulated DC voltage of 24V DC with a residual ripple of <5% under nominal conditions.
Transformers
GN GGN (1-phase)
Applications
24V DC power supplies based on the proven, reliable and robust 50Hz technology. The output voltage of these unregulated power supplies meets the requirements of DIN19240 with mains fluctuations of ± 10% of the supply voltages, the residual ripple of the output current is below 5%, typically about 3%.
DC power supply 24V acc.IEC/DIN 60950Pri: 230V AC or 115/230/400V AC with Sec: 24V
Applications
24V DC power supplies based on the proven, reliable and robust 50Hz technology. The output voltage of these unregulated power supplies meets the requirements of DIN19240 with mains fluctuations of ± 10% of the supply voltages, the residual ripple of the output current is below 5%, typically about 3%.
Railway Transformers
Fields of applications
Railway transformers for generall applications such as safe isolation of vehicle power supply.
Isolating transformers secure safe galvanic separation between primary and secondary winding.
Water-cooled transformersliquid cooled transformer as liquid cooled autotransformer or isolating transformer according IEC/DIN EN61558-2-13 and IEC/DIN EN61558-2-4
Applications
Liquid-cooled transformers of the Schmidbauer WKT series are excellently suited for water-cooled inverter technology. A potential-free water cooling simplifies water cooling in the entire system.
3 Phase Isolating Transformer / Vertical mounting versionDTS 0.1 - 2.0kVA according to IEC/DIN EN61558-2-4
3 phase isolating transformer according to EN61558-2-4. protection class I ready. Due to innovative vacuum impregnation in polyester varnish, the noise level is extraordinary low. Screw terminals are contact proof according to VBG4.
Standard switching matrix: Yyn0 (max. typical star load of phase current: approx. 10%). Switching matrix: Please note the distinction between different voltages (e.g. phase voltage, line voltage). For further information, don´t hesitate to contact us!
3 Phase Isolating Transformer / Vertical mounting versionDTS 2.0 - 5.0kVA according to IEC/DIN EN61558-2-4
3 phase isolating transformer according to EN61558-2-4. protection class I ready. Due to innovative vacuum impregnation in polyester varnish, the noise level is extraordinary low. Screw terminals are contact proof according to VBG4.
Any switching matrix can be realized. Standard switching matrix: Yyn0 (max. typical star load of phase current: approx. 10%). Switching matrix: Please note the distinction between different voltages (e.g. phase voltage, line voltage).
3 Phase Isolating Transformer / Vertical mounting versionDTS 5.0 - 35kVA according to IEC/DIN EN61558-2-4
3 phase isolating transformer according to EN61558-2-4. protection class I ready. Due to innovative vacuum impregnation in polyester varnish, the noise level is extraordinary low. Screw terminals are contact proof according to VBG4.
Standard switching matrix: Yyn0 (max. typical star load of phase current: approx. 10%). Switching matrix: Please note the distinction between different voltages (e.g. phase voltage, line voltage).
3 Phase Isolating Transformer with Module Core; Vertical mounting versionDTM 25 - 630kVA according to IEC/DIN EN61558-2-4
3 phase isolating transformer according to EN61558-2-4. protection class I ready. Due to innovative vacuum impregnation in polyester varnish, the noise level is extraordinary low. Screw terminals are contact proof according to VBG4.
Standard switching matrix: Dyn5 (max. typical star load of phase current: 100%). Switching matrix: Please note the distinction between different voltages (e.g. phase voltage, line voltage). Final operation position must allow natural convection through coolant bores. For further information, don’t hesitate to contact us.
3 Phase Isolating Transformer; Horizontal mounting versionDTL 0.25 - 2.0kVA according to IEC/DIN EN61558-2-4
3 phase isolating transformer according to IEC/EN61558-2-4 for general applications, e.g. for providing electrical (galvanic) isolation according to VDE0700/EN60335 regulations or network supply transformer (e.g. TN network system).