overviewtechnical dataPDF data sheet
Low profile safety transformer
Low profile safety transformer according to IEC/EN61558-2-6 suitable for general applications with double or reinforced insulation – max. output voltage: 50 V. E.g. electrical isolation for use in devices, built according to VDE0805/EN60950 regulations.
Specifications
- Ultra flat PDB type transformers for use in ultra small power supplies.
- Short-circuit proof construction.
- Transformer completely sealed with polyurethane varnish in polyamide mold.
- Additional fixing with 4 screws 2.9 x 9,5 e.g. DIN7981 possible.
- PTF-UI39 transformers can be customer-specified, e.g. output characteristics, temperature rise for nominal operation/ open-circuit, PRI/SEC voltages, pinning.
1 phase safety transformer PCB version according to IEC/EN61558-2-6
- extremly low profile
- Connections: Solder pins
- Optional screw supported mounting possible
- Any mounting position or angle possible
- completely sealed with polyurethane varnish in polyamide mold
Ua rated = Rated output voltage
Ua empty = Open-circuit output voltage
Rated power VA |
PRI Voltage V |
PRI A |
Ua empty Ua rated V |
Height mm |
Copper weight KG |
Total weight KG |
Core size | Type |
10 | 2×115 | 0,13 /0,065 | 1,37 | 21,7 | 0,12 | 0,265 | UI39/8 | PTF100 |
14 | 2×115 | 0,20/0,10 | 1,46 | 23,8 | 0,125 | 0,32 | UI39/10,2 | PTF140 |
18 | 2×115 | 0,22/0,11 | 1,30 | 27,1 | 0,13 | 0,37 | UI39/13,5 | PTF180 |
24 | 2×115 | 0,28/0,14 | 1,26 | 30,8 | 0,14 | 0,46 | UI39/17 | PTF240 |
30 | 2×115 | 0,38/0,19 | 1,29 | 34,8 | 0,16 | 0,53 | UI39/21 | PTF300 |